 Instructions
on Forcing a Dump on a S85/7017 After a System Hang 
 
  
 
 Operator
Panel and Power Control The above diagram shows the locations of the
operator panel display and the operator panel. 
 1
Operator Panel Display 
 2
Scroll Up Pushbutton 
 3
Scroll Down Pushbutton 
 4
Enter Pushbutton 
 5
Attention LED 
 6
Power On LED 
 7
Serial Number 
 8
Power Pushbutton 
 To
force a dump from the Operator Panel on the S85, use the following
procedure. 
 
	Using
	the Scroll Up or Down Button, Select function 22 onthe operator
	panel and press Enter. The response A1003022 displays on the
	operator panel.Using
	the Scroll Up or Down Button, Select function 22 again and press
	Enter. The response D1823080 displays on the operator panel. This
	indicated the dump request has been accepted by AIX, and the process
	continues, displaying 4-character progress messages.When
	the dump is complete the system automatically powers off. At this
	point you will need to Push the Power Pushbutton to start the
	system. Note:
	the system administrator may be able to start the system from the
	remote console at this point. Contact the System Administrator to
	ascertain whether pushing the power button is necessary. 
 |  
 |  |