Home About BC DR HA Support Training Download
You are here: Home/ Business-Continuity/ Please Login or Register

Additional documents of interest

  • Successful Business Continuity - Part 1 - Users and Groups
    This article was published in the April 2005 issue of AIX Update magazine and discusses system administration needs and requirements oriented around users and groups. The overall emphasis of this series of articles is for implementation of enterprise wide unique identifiers for a variety of parameters, such as user names, group names, UID and GID numbers.
  • Successful Business Continuity - Part 2 - Machine and Host Names
    This article was published in the May 2005 issue of AIX Update magazine and discusses naming structures for machines, systems, adapters, and aliases. The overall emphasis of this series of articles is for implementation of enterprise wide unique identifiers for a variety of parameters.
  • Successful Business Continuity - Part 3 - Volume Names
    This article was published in the December 2005 issue of AIX Update magazine and discusses naming structures for volume groups, logical volumes, log logical volumes, directory mount points, etc. The overall emphasis of this series of articles is for implementation of enterprise wide unique identifiers for a variety of parameters.
  • Successful Business Continuity - Part 4 - MQ Series, Startup/Shutdown Scripts, Error Processing
    This article was published in the April 2006 issue of AIX Update magazine and discusses how to implement AIX in an environment dedicated to business continuity. The topic of this article is the assignment of MQ Series queue names and aliases, resource group startup and shutdown script names (Application startup/shutdown script names), error logging, and error notification.
  • Successful Business Continuity - Part 5 - Miscellaneous topics
    This article was published in the August 2006 issue of AIX Update magazine and discusses how to implement AIX in an environment dedicated to business continuity. A variety of topics is discussed in this article including automated documentation generation and management.
  • Automated Microcode Management System
    One of the most difficult administration tasks in an AIX environment is attempting to keep the firmware and microcode up-to-date. Mt Xia has devised an automated method of gathering the Microcode information, determining which microcode needs to be updated, generating reports, and uploading the required microcode updates to each individual system.
  • Calculating the size of a Virtual Processor
    This document describes the algorithms used to calculate the size of a virtual processor when using shared processors in an LPAR. The IBM documentation describes how to calculate CPU utilization, NOT how to size for configuration, this document clarifies this process. A description of the HMC input fields for the processor tab is included.
  • Basics of Partition Load Manager Setup
    This presentation was provided by Ron Barker from IBM regarding the PLM Basic setup.
  • ppt
  • pdf
  • HMC Standards

    Contained here are the standards for defining new LPAR's in the Power5/6/7 architecture environment using the Hardware Management Console. These standards describe the information required to define the LPAR's and the format in which this information should be presented.

    This environment utilizes the VIO server to virtualize the hardware I/O adapters to client LPAR's, thus allowing multiple LPAR's to share resources. Implementation of this type of environment requires extensive up-front design work and planning. Each hardware adapter must be identified to the VIO server and virtualized for use by each client LPAR.

    To begin configuring this environment, build a spreadsheet to contain all frame and I/O adapter information, this spreadsheet should contain at least the following:

    Frame Type:                                 
    Frame S/N:                                 
    System Name:                                 
    CPUs                                 
    RAM (GB)                                 
    CUoD CPUs                                 
    CUoD RAM (GB)                                 

    Drawer Serial Bus Slot Adapter LPAR
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                
                                                                                                                                


    Much of this information can be automatically generated using the script "hmcparse.ksh". Example results from this script follow:

    Server9119590SN51A432B

    Drawer Serial Bus Slot Adapter LPAR
    U5791.001.91800WT-P1 13 T6 SCSI bus controller dalapvio01
    U5791.001.91800WT-P1 13 C08 Fibre Channel Serial Bus dalpocdb01
    U5791.001.91800WT-P1 13 C09 Empty slot  
    U5791.001.91800WT-P1 13 C10 Empty slot  
    U5791.001.91800WT-P1 14 C01 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P1 14 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WT-P1 14 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P1 14 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WT-P1 15 T5 SCSI bus controller dalapvio01
    U5791.001.91800WT-P1 15 C05 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P1 15 C06 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P1 15 C07 Empty slot  
    U5791.001.91800WT-P2 19 T6 SCSI bus controller dalapvio01
    U5791.001.91800WT-P2 19 C08 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P2 19 C09 Empty slot  
    U5791.001.91800WT-P2 19 C10 Other Communications Device  
    U5791.001.91800WT-P2 20 C01 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P2 20 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 20 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 20 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 21 T5 SCSI bus controller dalapvio01
    U5791.001.91800WT-P2 21 C05 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P2 21 C06 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P2 21 C07 Empty slot  
    U5791.001.91800WW-P1 10 T6 SCSI bus controller dalapvio02
    U5791.001.91800WW-P1 10 C08 Fibre Channel Serial Bus dalpocdb01
    U5791.001.91800WW-P1 10 C09 Empty slot  
    U5791.001.91800WW-P1 10 C10 Storage controller dalapvio01
    U5791.001.91800WW-P1 11 C01 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P1 11 C02 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 11 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 11 C04 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 12 T5 SCSI bus controller dalapvio02
    U5791.001.91800WW-P1 12 C05 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P1 12 C06 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P1 12 C07 Empty slot  
    U5791.001.91800WW-P2 16 T6 SCSI bus controller dalapvio02
    U5791.001.91800WW-P2 16 C08 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P2 16 C09 Empty slot  
    U5791.001.91800WW-P2 16 C10 Other Communications Device  
    U5791.001.91800WW-P2 17 C01 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P2 17 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WW-P2 17 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P2 17 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WW-P2 18 T5 SCSI bus controller dalapvio02
    U5791.001.91800WW-P2 18 C05 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P2 18 C06 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P2 18 C07 Empty slot  
    U5791.001.91800WT-P1 13 T6 SCSI bus controller dalapvio01
    U5791.001.91800WT-P1 13 C08 Fibre Channel Serial Bus dalpocdb01
    U5791.001.91800WT-P1 13 C09 Empty slot  
    U5791.001.91800WT-P1 13 C10 Empty slot  
    U5791.001.91800WT-P1 14 C01 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P1 14 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WT-P1 14 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P1 14 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WT-P1 15 T5 SCSI bus controller dalapvio01
    U5791.001.91800WT-P1 15 C05 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P1 15 C06 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P1 15 C07 Empty slot  
    U5791.001.91800WT-P2 19 T6 SCSI bus controller dalapvio01
    U5791.001.91800WT-P2 19 C08 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P2 19 C09 Empty slot  
    U5791.001.91800WT-P2 19 C10 Other Communications Device  
    U5791.001.91800WT-P2 20 C01 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P2 20 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 20 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 20 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 21 T5 SCSI bus controller dalapvio01
    U5791.001.91800WT-P2 21 C05 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P2 21 C06 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P2 21 C07 Empty slot  
    U5791.001.91800WW-P1 10 T6 SCSI bus controller dalapvio02
    U5791.001.91800WW-P1 10 C08 Fibre Channel Serial Bus dalpocdb01
    U5791.001.91800WW-P1 10 C09 Empty slot  
    U5791.001.91800WW-P1 10 C10 Storage controller dalapvio01
    U5791.001.91800WW-P1 11 C01 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P1 11 C02 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 11 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 11 C04 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 12 T5 SCSI bus controller dalapvio02
    U5791.001.91800WW-P1 12 C05 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P1 12 C06 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P1 12 C07 Empty slot  
    U5791.001.91800WW-P2 16 T6 SCSI bus controller dalapvio02
    U5791.001.91800WW-P2 16 C08 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P2 16 C09 Empty slot  
    U5791.001.91800WW-P2 16 C10 Other Communications Device  
    U5791.001.91800WW-P2 17 C01 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P2 17 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WW-P2 17 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P2 17 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WW-P2 18 T5 SCSI bus controller dalapvio02
    U5791.001.91800WW-P2 18 C05 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P2 18 C06 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P2 18 C07 Empty slot  


    Server9119590SN51A432C

    Drawer Serial Bus Slot Adapter LPAR
    U5791.001.91800WR-P1 13 T6 SCSI bus controller dalapvio04
    U5791.001.91800WR-P1 13 C08 Fibre Channel Serial Bus dalpocdb02
    U5791.001.91800WR-P1 13 C09 Empty slot  
    U5791.001.91800WR-P1 13 C10 Empty slot  
    U5791.001.91800WR-P1 14 C01 PCI 1Gbps Ethernet dalapvio04
    U5791.001.91800WR-P1 14 C02 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WR-P1 14 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WR-P1 14 C04 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WR-P1 15 T5 SCSI bus controller dalapvio04
    U5791.001.91800WR-P1 15 C05 PCI 1Gbps Ethernet dalapvio04
    U5791.001.91800WR-P1 15 C06 Fibre Channel Serial Bus dalapvio04
    U5791.001.91800WR-P1 15 C07 Empty slot  
    U5791.001.91800WR-P2 19 T6 SCSI bus controller dalapvio04
    U5791.001.91800WR-P2 19 C08 Fibre Channel Serial Bus dalapvio04
    U5791.001.91800WR-P2 19 C09 Empty slot  
    U5791.001.91800WR-P2 19 C10 Other Communications Device  
    U5791.001.91800WR-P2 20 C01 PCI 1Gbps Ethernet dalapvio04
    U5791.001.91800WR-P2 20 C02 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WR-P2 20 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio04
    U5791.001.91800WR-P2 20 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio04
    U5791.001.91800WR-P2 21 T5 SCSI bus controller dalapvio04
    U5791.001.91800WR-P2 21 C05 PCI 1Gbps Ethernet dalapvio04
    U5791.001.91800WR-P2 21 C06 Fibre Channel Serial Bus dalapvio04
    U5791.001.91800WR-P2 21 C07 Empty slot  
    U5791.001.91800WY-P1 10 T6 SCSI bus controller dalapvio03
    U5791.001.91800WY-P1 10 C08 Fibre Channel Serial Bus dalpocdb02
    U5791.001.91800WY-P1 10 C09 Empty slot  
    U5791.001.91800WY-P1 10 C10 Storage controller dalapvio03
    U5791.001.91800WY-P1 11 C01 PCI 1Gbps Ethernet dalapvio03
    U5791.001.91800WY-P1 11 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio04
    U5791.001.91800WY-P1 11 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio03
    U5791.001.91800WY-P1 11 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio04
    U5791.001.91800WY-P1 12 T5 SCSI bus controller dalapvio03
    U5791.001.91800WY-P1 12 C05 PCI 1Gbps Ethernet dalapvio03
    U5791.001.91800WY-P1 12 C06 Fibre Channel Serial Bus dalapvio03
    U5791.001.91800WY-P1 12 C07 Empty slot  
    U5791.001.91800WY-P2 16 T6 SCSI bus controller dalapvio03
    U5791.001.91800WY-P2 16 C08 Fibre Channel Serial Bus dalapvio03
    U5791.001.91800WY-P2 16 C09 Empty slot  
    U5791.001.91800WY-P2 16 C10 Other Communications Device  
    U5791.001.91800WY-P2 17 C01 PCI 1Gbps Ethernet dalapvio03
    U5791.001.91800WY-P2 17 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio03
    U5791.001.91800WY-P2 17 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio03
    U5791.001.91800WY-P2 17 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio03
    U5791.001.91800WY-P2 18 T5 SCSI bus controller dalapvio03
    U5791.001.91800WY-P2 18 C05 PCI 1Gbps Ethernet dalapvio03
    U5791.001.91800WY-P2 18 C06 Fibre Channel Serial Bus dalapvio03
    U5791.001.91800WY-P2 18 C07 Empty slot  


    Server9119590SN51A432B

    Drawer Serial Bus Slot Adapter LPAR
    U5791.001.91800WT-P1 13 T6 SCSI bus controller dalapvio01
    U5791.001.91800WT-P1 13 C08 Fibre Channel Serial Bus dalpocdb01
    U5791.001.91800WT-P1 13 C09 Empty slot  
    U5791.001.91800WT-P1 13 C10 Empty slot  
    U5791.001.91800WT-P1 14 C01 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P1 14 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WT-P1 14 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P1 14 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WT-P1 15 T5 SCSI bus controller dalapvio01
    U5791.001.91800WT-P1 15 C05 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P1 15 C06 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P1 15 C07 Empty slot  
    U5791.001.91800WT-P2 19 T6 SCSI bus controller dalapvio01
    U5791.001.91800WT-P2 19 C08 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P2 19 C09 Empty slot  
    U5791.001.91800WT-P2 19 C10 Other Communications Device  
    U5791.001.91800WT-P2 20 C01 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P2 20 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 20 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 20 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 21 T5 SCSI bus controller dalapvio01
    U5791.001.91800WT-P2 21 C05 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P2 21 C06 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P2 21 C07 Empty slot  
    U5791.001.91800WW-P1 10 T6 SCSI bus controller dalapvio02
    U5791.001.91800WW-P1 10 C08 Fibre Channel Serial Bus dalpocdb01
    U5791.001.91800WW-P1 10 C09 Empty slot  
    U5791.001.91800WW-P1 10 C10 Storage controller dalapvio01
    U5791.001.91800WW-P1 11 C01 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P1 11 C02 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 11 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 11 C04 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 12 T5 SCSI bus controller dalapvio02
    U5791.001.91800WW-P1 12 C05 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P1 12 C06 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P1 12 C07 Empty slot  
    U5791.001.91800WW-P2 16 T6 SCSI bus controller dalapvio02
    U5791.001.91800WW-P2 16 C08 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P2 16 C09 Empty slot  
    U5791.001.91800WW-P2 16 C10 Other Communications Device  
    U5791.001.91800WW-P2 17 C01 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P2 17 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WW-P2 17 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P2 17 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WW-P2 18 T5 SCSI bus controller dalapvio02
    U5791.001.91800WW-P2 18 C05 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P2 18 C06 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P2 18 C07 Empty slot  
    U5791.001.91800WT-P1 13 T6 SCSI bus controller dalapvio01
    U5791.001.91800WT-P1 13 C08 Fibre Channel Serial Bus dalpocdb01
    U5791.001.91800WT-P1 13 C09 Empty slot  
    U5791.001.91800WT-P1 13 C10 Empty slot  
    U5791.001.91800WT-P1 14 C01 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P1 14 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WT-P1 14 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P1 14 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WT-P1 15 T5 SCSI bus controller dalapvio01
    U5791.001.91800WT-P1 15 C05 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P1 15 C06 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P1 15 C07 Empty slot  
    U5791.001.91800WT-P2 19 T6 SCSI bus controller dalapvio01
    U5791.001.91800WT-P2 19 C08 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P2 19 C09 Empty slot  
    U5791.001.91800WT-P2 19 C10 Other Communications Device  
    U5791.001.91800WT-P2 20 C01 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P2 20 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 20 C03 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 20 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio01
    U5791.001.91800WT-P2 21 T5 SCSI bus controller dalapvio01
    U5791.001.91800WT-P2 21 C05 PCI 1Gbps Ethernet dalapvio01
    U5791.001.91800WT-P2 21 C06 Fibre Channel Serial Bus dalapvio01
    U5791.001.91800WT-P2 21 C07 Empty slot  
    U5791.001.91800WW-P1 10 T6 SCSI bus controller dalapvio02
    U5791.001.91800WW-P1 10 C08 Fibre Channel Serial Bus dalpocdb01
    U5791.001.91800WW-P1 10 C09 Empty slot  
    U5791.001.91800WW-P1 10 C10 Storage controller dalapvio01
    U5791.001.91800WW-P1 11 C01 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P1 11 C02 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 11 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 11 C04 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P1 12 T5 SCSI bus controller dalapvio02
    U5791.001.91800WW-P1 12 C05 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P1 12 C06 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P1 12 C07 Empty slot  
    U5791.001.91800WW-P2 16 T6 SCSI bus controller dalapvio02
    U5791.001.91800WW-P2 16 C08 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P2 16 C09 Empty slot  
    U5791.001.91800WW-P2 16 C10 Other Communications Device  
    U5791.001.91800WW-P2 17 C01 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P2 17 C02 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WW-P2 17 C03 PCI 10/100Mbps Ethernet w/ IPSec  
    U5791.001.91800WW-P2 17 C04 PCI 10/100Mbps Ethernet w/ IPSec dalapvio02
    U5791.001.91800WW-P2 18 T5 SCSI bus controller dalapvio02
    U5791.001.91800WW-P2 18 C05 PCI 1Gbps Ethernet dalapvio02
    U5791.001.91800WW-P2 18 C06 Fibre Channel Serial Bus dalapvio02
    U5791.001.91800WW-P2 18 C07 Empty slot  


    Configuring Virtual Ethernet Adapters

    Configuring virtual ethernet adapters for use in Mt Xia's high availability environment requires configuration of multiple server side ethernet adapters as well as multiple client side adapters. Each VIO server will have one server side ethernet adapter that can be shared to all client LPAR's requiring virtual ethernet adapters.

    This document describes a standard for establishing virtual ethernet adapters in the VIO Server environment. This standard is specific to the numbering scheme used to identify the VLAN ID's of the virtual ethernet adapters. The VLAN ID number is also referred to in the HMC as the PVID number.

    This document assumes there are two VIO servers in the environment and the names of the VIO servers are represented by "*vio0" and "*vio5".

    The VLAN ID numbers will be three digit numbers, each digit representing a different aspect of the underlying ethernet adapter.

    3 Digit VLAN ID Number
    First Digit Second Digit Third Digit
    5: Boot/Service
    6: Standby
    7: Backup
    8: Management
    9: Intra-Frame
    0: Gigabit
    5: 10/100
    9: Bus
    0,2,4,6,8: VIO Server with even numbered hostnames
    1,3,5,7,9: VIO Server with odd numberd hostnames

    The first digit of the VLAN ID numbers associated with virtual ethernet adapters will be used to represent a variety of adapter purposes. Those purposes include boot, standby, backup, management, and intra-frame communications.

    • 500-599: boot/service
    • 600-699: standby
    • 700-799: backup
    • 800-899: management
    • 900-999: intra-frame


    The third digit of the three digit VLAN ID number assigned to virtual ethernet adapters associated with the VIO Server named *vio0 will end with a number between 0 and 4.

    Example: 500, 501, 502, 510, 520, 521, ...

    The VLAN ID numbers assigned to virtual ethernet adapters associated with the VIO Server named *vio5 will end with an odd number beginning at 5.

    Example: 505, 506, 507, 515, 525, 526, ...


    The second digit of the three digit VLAN ID sequence will represent the adapter speed, gigabit cards will be represented by 0 thru 4, 10/100 adapters by 5 thru 8, and bus speed adapters by a 9. This digit may be reconfigured as necessary.

    Examples:

    Adapter Speed
    VLAN ID Adapter Type Adapter Speed VIO Server
    500 Boot 0 Gigabit *vio0
    501 Boot 1 Gigabit *vio0
    505 Boot 0 Gigabit *vio5
    506 Boot 1 Gigabit *vio5
           
    550 Boot 0 10/100 *vio0
    551 Boot 1 10/100 *vio0
    555 Boot 0 10/100 *vio5
    556 Boot 1 10/100 *vio5
           
    590 Boot 0 Bus *vio0
    591 Boot 0 Bus *vio0
    595 Boot 0 Bus *vio5
    596 Boot 1 Bus *vio5


    An LPAR may have multiple adapters of a variety of types, for example an LPAR that provides database services and is a member of an HACMP cluster may have boot, standby, management, backup, and intra-frame virtual adapters as follows:

    • Gigabit adapter used for boot/service address
    • Gigabit adapter used for standby address
    • 10/100 backup adapter
    • 10/100 management adapter
    • 2 intra-frame adapters

    VIO Server Configuration:
    VLAN ID Adapter Type Adapter Speed VIO Server
    500 Boot Gigabit *vio0
    600 Standby Gigabit *vio0
    750 Backup 10/100 *vio0
    850 Management 10/100 *vio0
    990 Intra-frame Bus *vio0
    991 Intra-frame Bus *vio0
           
    505 Boot Gigabit *vio5
    605 Standby Gigabit *vio5
    755 Backup 10/100 *vio5
    855 Management 10/100 *vio5
    995 Intra-frame Bus *vio5
    996 Intra-frame Bus *vio5

    LPAR VLAN ID configuration to utilize virtual adapters:
    VLAN ID Adapter Type Adapter Speed VIO Server
    500 Boot Gigabit *vio0
    505 Boot Gigabit *vio5
    600 Standby Gigabit *vio0
    605 Standby Gigabit *vio5
    750 Backup 10/100 *vio0
    755 Backup 10/100 *vio5
    850 Management 10/100 *vio0
    855 Management 10/100 *vio5
    990 Intra-frame Bus *vio0
    991 Intra-frame Bus *vio0
    995 Intra-frame Bus *vio5
    996 Intra-frame Bus *vio5

    This virtual ethernet information can be automatically gathered from an existing frame through the HMC using the script "virtualeth.ksh. Example output from this script follows:


    Server9119590SN51A432B

    Adapter Type Slot Trunk Device Port Virtual LAN ID MAC Address LPAR Name
    server 10 1 595 12F3F000200A dalapvio01
    server 20 1 593 12F3F0002014 dalapvio01
    server 15 1 594 12F3F000300F dalapvio02
    server 25 1 592 12F3F0003019 dalapvio02
    client 10 0 595 12F3F000500A dalpocap01
    client 15 0 594 12F3F000500F dalpocap01
    client 20 0 593 12F3F0005014 dalpocap01
    client 25 0 592 12F3F0005019 dalpocap01
    client 10 0 595 12F3F000600A dalpocap02
    client 15 0 594 12F3F000600F dalpocap02
    client 20 0 593 12F3F0006014 dalpocap02
    client 25 0 592 12F3F0006019 dalpocap02
    client 10 0 595 12F3F000700A dalpocap03
    client 15 0 594 12F3F000700F dalpocap03
    client 20 0 593 12F3F0007014 dalpocap03
    client 25 0 592 12F3F0007019 dalpocap03
    client 10 0 595 12F3F000400A dalpocdb01
    client 15 0 594 12F3F000400F dalpocdb01
    client 20 0 593 12F3F0004014 dalpocdb01
    client 25 0 592 12F3F0004019 dalpocdb01


    Server9119590SN51A432C

    Adapter Type Slot Trunk Device Port Virtual LAN ID MAC Address LPAR Name
    client 520 0 520 EE9530001208 dalapplm73
    client 525 0 525 EE953000120D dalapplm73
    server 10 1 510 EE953000300A dalapvio03
    server 20 1 520 EE9530003014 dalapvio03
    server 15 1 515 EE953000400F dalapvio04
    server 25 1 525 EE9530004019 dalapvio04
    client 10 0 510 EE953000500A dalpocdb02
    client 15 0 515 EE953000500F dalpocdb02
    client 20 0 520 EE9530005014 dalpocdb02
    client 25 0 525 EE9530005019 dalpocdb02


    Configuring Virtual SCSI Adapters

    Configuration of the virtual I/O adapters requires the knowledge of disk layouts as well as networking configuration. The virtual SCSI adapters require server and client side adapters to be configured on the HMC. The server side portion of the SCSI adapter, configured on the VIO, requires a frame wide unique "slot number" be defined. For high availability a server side portion of the SCSI adapter must be configured for each VIO server. This means that each virtual disk or logical volume connection is associated with two server side SCSI adapters, one on each VIO server. By convention the standard has become that each SCSI adapter is numbered as a multiple of 10, with the first SCSI adapter of the server side high availability pair being configured on the first VIO server and ending with the number 0, i.e., 210, 220, 230, 240, ... The second SCSI adapter of the server side high availability pair is configured on the second VIO server and ends with the number 5, i.e., 215, 225, 235, 245, ...

    For each LPAR that uses virtual disk or logical volumes, a client side virtual SCSI adapter must be configured on the HMC. The client side of the virtual SCSI adapter requires additional information and it's settings to correspond with the server side of the SCSI adapter. Coordination of the slot numbers defined here will make debugging and tracking of problems much easier and is highly desired. The information required to configure a client side SCSI adapter includes slot number, the name of the server side SCSI adapter remote partition, and the slot number of the server side SCSI adapter on the remote partition. The client side slot number should correspond with the server side slot number to make debugging and tracking easier. As an example of defining both server and client side SCSI adapters in a high availability environment:

    For each LPAR, a pair of virtual SCSI adapters shall be configured to be used for attachment of the operating system and paging disks. Another pair of virtual SCSI adapters shall be configured for the purpose of application disk attachment. The virtual SCSI adapters designated for use as operating system disk attachment shall be numbered between 10 and 199. The virtual SCSI adapters designated for use as application disk attachment shall be numbered between 200 and 499.

    Using this standard, each VIO server will have one virtual SCSI adapter per LPAR for the operating system, and one virtual SCSI adapter per LPAR for the application storage. Each LPAR will reference two virtual SCSI adapters, one from each VIO server, for the operating system storage, and two virtual SCSI adapters, one from each VIO server, for the application storage. Examples of this is shown below.

    Example Virtual SCSI Slot Numbers
    LPAR VIO 0
    OS Slot
    VIO 1
    OS Slot
    VIO 0
    Appl Slot
    VIO 1
    Appl Slot
    daladcal01 10 15 200 205
    daladfim03 20 25 210 215
    daladesp01 30 35 220 225
    dalapega01 40 45 230 235
    dalaaora02 50 55 240 245

    Each virtual SCSI adapter may have one or more disks with it, depending upon the LPAR requirements. These disk associations are performed on the VIO server by referencing the slot numbers assigned to each LPAR.


    This virtual SCSI adapter information can be automatically gathered from an existing frame through the HMC using the script "virtualscsi.ksh. Example output from this script follows:


    Server9119590SN51A432B

    Adapter Type Slot Remote LPAR Remote Slot Backing Device LPAR Name
    server 100 any 0x8100000000000000//ap01rootlv dalapvio01
    server 110 any 0x8100000000000000//ap02rootlv dalapvio01
    server 120 any 0x8100000000000000//ap03rootlv dalapvio01
    server 130 any 0x8100000000000000//db01rootlv dalapvio01
    server 150 any 0x8100000000000000/U5791.001.91800WT-P1-C06-T1-W50060E8003334713-L1000000000000/hdisk5 dalapvio01
    server 160 any 0x8100000000000000/U5791.001.91800WT-P1-C06-T1-W50060E8003334713-L2000000000000/hdisk6 dalapvio01
    server 170 any 0x8100000000000000/U5791.001.91800WT-P1-C06-T1-W50060E8003334713-L3000000000000/hdisk7 dalapvio01
    client 190 dalapvio01 190 none dalpocdb01
    server 30 any 0x8100000000000000//pocap01lv dalapvio01
    server 40 any 0x8100000000000000//pocap02lv dalapvio01
    server 50 any 0x8100000000000000//pocap03lv dalapvio01
    server 60 any 0x8100000000000000//pocdb01lv dalapvio01
    server 105 any // dalapvio02
    server 115 any // dalapvio02
    server 125 any // dalapvio02
    server 135 any // dalapvio02
    server 155 any 0x8100000000000000/U5791.001.91800WW-P1-C06-T1-W50060E8003334703-L1000000000000/hdisk5 dalapvio02
    server 165 any 0x8100000000000000/U5791.001.91800WW-P1-C06-T1-W50060E8003334703-L2000000000000/hdisk6 dalapvio02
    server 175 any 0x8100000000000000/U5791.001.91800WW-P1-C06-T1-W50060E8003334703-L3000000000000/hdisk7 dalapvio02
    client 195 dalapvio02 195 none dalpocdb01
    server 35 any 0x8100000000000000//pocap01lv dalapvio02
    server 45 any 0x8100000000000000//pocap02lv dalapvio02
    server 55 any 0x8100000000000000//pocap03lv dalapvio02
    server 65 any 0x8100000000000000//pocdb01lv dalapvio02
    client 2 dalapvio01 60 none dalpocdb01
    client 3 dalapvio02 65 none dalpocdb01
    client 4 dalapvio01 130 none dalpocdb01
    client 5 dalapvio01 170 none dalpocap03
    client 6 dalapvio02 175 none dalpocap03
    client 2 dalapvio01 60 none dalpocdb01
    client 3 dalapvio02 65 none dalpocdb01
    client 4 dalapvio01 130 none dalpocdb01
    client 5 dalapvio01 170 none dalpocap03
    client 6 dalapvio02 175 none dalpocap03
    client 2 dalapvio01 60 none dalpocdb01
    client 3 dalapvio02 65 none dalpocdb01
    client 4 dalapvio01 130 none dalpocdb01
    client 5 dalapvio01 170 none dalpocap03
    client 6 dalapvio02 175 none dalpocap03
    client 190 dalapvio01 190 none dalpocdb01
    client 195 dalapvio02 195 none dalpocdb01
    client 2 dalapvio01 60 none dalpocdb01
    client 3 dalapvio02 65 none dalpocdb01
    client 4 dalapvio01 130 none dalpocdb01


    Server9119590SN51A432C

    Adapter Type Slot Remote LPAR Remote Slot Backing Device LPAR Name
    server 140 any 0x8100000000000000//s32Cplmrootlv dalapvio03
    server 145 any 0x8100000000000000//i32Cplmrootlv dalapvio04
    server 130 any 0x8100000000000000//sdb02rootlv dalapvio03
    server 140 any 0x8100000000000000//s32Cplmrootlv dalapvio03
    client 190 dalapvio03 190 none dalpocdb02
    server 145 any 0x8100000000000000//i32Cplmrootlv dalapvio04
    client 195 dalapvio04 195 none dalpocdb02
    server 65 any 0x8100000000000000//db02rootlv dalapvio04
    client 190 dalapvio03 190 none dalpocdb02
    client 195 dalapvio04 195 none dalpocdb02
    client 2 dalapvio04 65 none dalpocdb02
    client 3 dalapvio03 130 none dalpocdb02

    -
    Standards
    -
     

    Policies
    Guidelines
    Procedures
    Config VEthnet
    Config VSCSI


    LPAR Leasing
    Lease an AIX / i5 LPAR
    Reduce your costs

    www.mtxia.com

    Server Leasing
    Lease a Server off-site
    Reduce your costs

    www.mtxia.com

    Data Center Automation
    Business Continuity and DR
    Virtualization/Consolidation

    www.mtxia.com

    HMC Service
    Hardware Management Console
    Manage Remote AIX / i5 LPARs

    www.siteox.com

    Business Web Site Hosting
    $3.99 / month includes Tools,
    Shopping Cart, Site Builder

    www.siteox.com

    FREE Domain Registration
    included with Web Site Hosting
    Tools, Social Networking, Blog

    www.siteox.com

    Disaster Recovery
    Small Business Oriented
    Off-Site Facilities

    www.mtxia.com

    IBM pSeries / iSeries
    Reduce your Costs
    Off-Site Server Hosting

    www.mtxia.com